Technical Specs:
Range of product Altistart 48
Product or component type Soft starter
Product destination Asynchronous motors
Product specific application Pumping and ventilation machine
Severe and standard applications
Component name ATS48
Power supply voltage 208…690 V (- 15…10 %)
Motor power kW 630 kW at 690 V for standard applications
630 kW at 660 V for standard applications
560 kW at 690 V for severe applications
560 kW at 660 V for severe applications
400 kW at 525 V for severe applications
400 kW at 500 V for severe applications
400 kW at 440 V for standard applications
355 kW at 440 V for severe applications
355 kW at 400 V for standard applications
315 kW at 400 V for severe applications
160 kW at 230 V for severe applications
Motor power hp 600 hp at 575 V for standard applications
500 hp at 575 V for severe applications
500 hp at 460 V for standard applications
400 hp at 460 V for severe applications
250 hp at 230 V for standard applications
200 hp at 230 V for severe applications
200 hp at 208 V for standard applications
Power dissipation in W 1958 W for standard applications
1731 W for standard applications
Utilisation category AC-53A
Type of start Start with torque control (current limited to 5 In)
Icl nominal current 660 A for standard applications
590 A for standard applications
IP degree of protection IP00
Height 26.37
Width 15.74
Depth 11.81
Product weight 113.31
Square D ATS48C66Y
Altistart 48 Orientated towards performance, intelligence and building protection. Dedicated HVAC* Focused on Building Management Systems (BMS). Easy integration to building supervision network using embedded protocols. Instant detection of system failure: belt breakage, pump running dry, phase failure, etc. Preventive maintenance for reducing costs: fault alert, operating time, etc. Energy consumption monitoring.
Focused on user-friendliness – Easy set-up, commissioning and diagnostics tools: remote graphic terminal (6 languages as standard), Multi-Loader, PC Software, Bluetooth capability and SoMove Mobile software. Compact size for better integration. Focused on cost savings – Reduced investment costs (embedded functionalities). Quick return on investment (energy saving). Focused on protection & efficiency – Continuity of service. Functions designed for buildings: fi re mode, damper monitoring, mechanical protection, etc. • Integrated EMC fi lter. • Antiharmonic technology (THDI ≈ 30%).
square d vfd, square d starter, square d motor starter